Centurion VECTOR2 Specifiche Pagina 1

Navigare online o scaricare Specifiche per Strumenti per giardinaggio Centurion VECTOR2. Centurion VECTOR2 Specifications Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 2

Page 10Item Description Qty. Part No.1 Wall bracket (high security) 1 1050M300002 Padlock 2 M-PLTRI2634 Vector high security kit packing leaflet 1 DOC

Pagina 3

Page 10Item Description Qty. Part No.1 Wall bracket (high security) 1 1050M300002 Padlock 2 M-PLTRI2634 Vector high security kit packing leaflet 1 DOC

Pagina 4 - Lightning Protection

Page 12Required Tools & EquipmentRequired Tools & EquipmentFigure 4 Required Tools and EquipmentSpanner17mm, 15mmPreferably Socket SetScrew Dr

Pagina 5

Page 12Required Tools & EquipmentRequired Tools & EquipmentFigure 4 Required Tools and EquipmentSpanner17mm, 15mmPreferably Socket SetScrew Dr

Pagina 6 - SpecificationsSpecifications

Page 15Site ConsiderationsSite ConsiderationsPage 14In order to ensure a reliable and durable installation thought should be given to:Strength of the

Pagina 7

Page 15Site ConsiderationsSite ConsiderationsPage 14In order to ensure a reliable and durable installation thought should be given to:Strength of the

Pagina 8 - (VEC40000V2 & VEC50000V2)

Cabling RequirementsCabling RequirementsFigure 6 Cabling RequirementsFigure 5 Minimum Installation RequirementsPage 171. 220V AC mains cable via mains

Pagina 9

Cabling RequirementsCabling RequirementsFigure 6 Cabling RequirementsFigure 5 Minimum Installation RequirementsPage 171. 220V AC mains cable via mains

Pagina 10

4. Secure the bracket to the wall with the most appropriate means.It is critical that the wall bracket is securely mounted. See page 14 for site cons

Pagina 11

4. Secure the bracket to the wall with the most appropriate means.It is critical that the wall bracket is securely mounted. See page 14 for site cons

Pagina 12 - Figure 3 Optional Accessories

CENTURION SYSTEMS has been manufacturing automatic gate systems since 1987, and is committed to providing reliable, cost effective solutions in the fi

Pagina 13

or13.Unlock the operator and open the gate fully.14. Slide the origin clamp along the actuator tube, right up to the operator.Secure in place with an

Pagina 14 - The Mechano kit

or13.Unlock the operator and open the gate fully.14. Slide the origin clamp along the actuator tube, right up to the operator.Secure in place with an

Pagina 15

Alternative positions A and B ‘min value’Gate swing A+B should Up to Up to Up to Up to Up to Up toangle not exceed 1.5m 2m 2.5m 3m 3.5m 4m60°

Pagina 16

Alternative positions A and B ‘min value’Gate swing A+B should Up to Up to Up to Up to Up to Up toangle not exceed 1.5m 2m 2.5m 3m 3.5m 4m60°

Pagina 17

Page 25Alternative positions A and B ‘min value’Gate swing A+B should Up to Up to Up to Up to Up to Up toangle not exceed 1.5m 2m 2.5m 3

Pagina 18 - Take care to shorten

Page 25Alternative positions A and B ‘min value’Gate swing A+B should Up to Up to Up to Up to Up to Up toangle not exceed 1.5m 2m 2.5m 3

Pagina 19

Electrical Set-upElectrical Set-upWARNING1. Always check that the isolator in the mains supply to the gate is in the OFF position, before doing any wo

Pagina 20 - Fasten gate bracket to gate

Electrical Set-upElectrical Set-upWARNING1. Always check that the isolator in the mains supply to the gate is in the OFF position, before doing any wo

Pagina 21

Figure 10 provides the full menu of features that can be set up on the system. Explanation of each feature is provided in the section “CONTROLLER FEAT

Pagina 22 - For V500 (500mm operator)

Figure 10 provides the full menu of features that can be set up on the system. Explanation of each feature is provided in the section “CONTROLLER FEAT

Pagina 23

CENTURION SYSTEMS has been manufacturing automatic gate systems since 1987, and is committed to providing reliable, cost effective solutions in the fi

Pagina 24 - Outward Swing Gate Setup

Page 30Figure 10 Part B of “Menu Navigation Map”Page 31Pedestrian Open Position: 7.1Pedestrian Autoclose Time: 7.2Pedestrian Pre-Open Delay: 7.3Pedest

Pagina 25

Page 30Figure 10 Part B of “Menu Navigation Map”Page 31Pedestrian Open Position: 7.1Pedestrian Autoclose Time: 7.2Pedestrian Pre-Open Delay: 7.3Pedest

Pagina 26 - Setting the limits

closed position and via the PCM, push the two gates into the fully closed position, but not past. SHORT STOP VALUEThe short stop distance can be set b

Pagina 27

closed position and via the PCM, push the two gates into the fully closed position, but not past. SHORT STOP VALUEThe short stop distance can be set b

Pagina 28 - Menu LevelMenu Level

Page 34 Page 35RAMP DOWN DISTANCE Sets the ramp-down distance in millimeters of travel of the piston when stopping. This setting applies to both motor

Pagina 29

Page 34 Page 35RAMP DOWN DISTANCE Sets the ramp-down distance in millimeters of travel of the piston when stopping. This setting applies to both motor

Pagina 30 - REMOTES: 11

Page 36 Page 37PEDESTRIAN OPENING – MENU 7This feature is associated with the PED input on the controller. When activating this input, the system will

Pagina 31

Page 36 Page 37PEDESTRIAN OPENING – MENU 7This feature is associated with the PED input on the controller. When activating this input, the system will

Pagina 32 - “Short Stop”

Page 38DIAGNOSTIC SCREEN STATUSAllow a diagnostic screen to be displayed. Can be useful when troubleshooting, but requires some technical knowledge.TE

Pagina 33

Page 38DIAGNOSTIC SCREEN STATUSAllow a diagnostic screen to be displayed. Can be useful when troubleshooting, but requires some technical knowledge.TE

Pagina 34 - Gates will not close

Important Safety InstructionsImportant Safety InstructionsPage 4To ensure the safety of people, it is important that you read all the following instru

Pagina 35

Page 41Page 40Description of Terminal FunctionsDescription of Terminal FunctionsS Sens1 Motor S (MTR S) operator . Connects to the thin PURPLE wire o

Pagina 36

Page 41Page 40Description of Terminal FunctionsDescription of Terminal FunctionsS Sens1 Motor S (MTR S) operator . Connects to the thin PURPLE wire o

Pagina 37

Page 42LED External gate status indicator. (A low current output signal.) An output terminal which provides a low current, drive (approx. 4,5V D

Pagina 38 - PARAMETER DESCRIPTION

Page 42LED External gate status indicator. (A low current output signal.) An output terminal which provides a low current, drive (approx. 4,5V D

Pagina 39

Charger and Pillar Light ConnectionsCharger and Pillar Light ConnectionsPage 44Use this procedure to accurately determine the gate opening angle:The f

Pagina 40

Charger and Pillar Light ConnectionsCharger and Pillar Light ConnectionsPage 44Use this procedure to accurately determine the gate opening angle:The f

Pagina 41

Figure 13 Wiring Diagram for Motor M Figure 14 Wiring Diagram for Motor S15151515S Sens1S Sens2M Sens1M Sense2Sens+Sens-Saf CLOSaf OPEComLCK/STPTRGPED

Pagina 42 - During Normal Operation

Figure 13 Wiring Diagram for Motor M Figure 14 Wiring Diagram for Motor S15151515S Sens1S Sens2M Sens1M Sense2Sens+Sens-Saf CLOSaf OPEComLCK/STPTRGPED

Pagina 43

Page 49COMNCNOOPENINGBEAM+12V/24VCOMNCNOIRB RECEIVER- 12V/24V12V or 24VIRB TxCLOSINGBEAM+12V/24VIRB RECEIVER- 12V/24V12V or 24VIRB TxS Sens1S Sens2M S

Pagina 44 - Fuse Protection

Page 49COMNCNOOPENINGBEAM+12V/24VCOMNCNOIRB RECEIVER- 12V/24V12V or 24VIRB TxCLOSINGBEAM+12V/24VIRB RECEIVER- 12V/24V12V or 24VIRB TxS Sens1S Sens2M S

Pagina 45

Important Safety InstructionsImportant Safety InstructionsPage 4To ensure the safety of people, it is important that you read all the following instru

Pagina 46 - Page 46 Page 47

Page 51Wiring diagram for other inputsWiring diagram for other inputsNEG+12V/24VCOMNCNORADIO RECEIVERREMOTE CONTROL CIRCUITRYNEG+12VCOMNCNOLOOPLOOP DE

Pagina 47

Page 51Wiring diagram for other inputsWiring diagram for other inputsNEG+12V/24VCOMNCNORADIO RECEIVERREMOTE CONTROL CIRCUITRYNEG+12VCOMNCNOLOOPLOOP DE

Pagina 48 - IRB RECEIVER

Page 52Wind speeds for which operator will still operate the gate (for V400 or V500 operators)For a 25% covered gate: (Palisades, etc.) x 1.8m highVal

Pagina 49

Page 52Wind speeds for which operator will still operate the gate (for V400 or V500 operators)For a 25% covered gate: (Palisades, etc.) x 1.8m highVal

Pagina 50 - LOOP DETECTOR

Page 54Installation DetailsInstallation Date:Installer's Name:Installer's Address:Installation Checked By:Installer's Telephone Number:

Pagina 51

Page 54Installation DetailsInstallation Date:Installer's Name:Installer's Address:Installation Checked By:Installer's Telephone Number:

Pagina 52

Sharecall 0860-CENTURION(Sharecall number applicable when dialed from within South Africa only)(Omit (0) when dialing from outside South Africa)or vis

Pagina 53

Power Configurations:Extention/retraction(no load):Max. Output Force:Max. Operations (day):Standby Operations:Standby period: ½ day 1 day 2 d

Pagina 54 - NotesNotes

Power Configurations:Extention/retraction(no load):Max. Output Force:Max. Operations (day):Standby Operations:Standby period: ½ day 1 day 2 d

Pagina 55

Page 8Allowable Gate MassMaximum allowable gate mass for V400 operator: Gate swing angle Up to Up to Up to Up to Up to Up to1.5m 2m 2.5m 3m(#1) 3.5m(

Pagina 56 - Sharecall 0860-CENTURION

Page 8Allowable Gate MassMaximum allowable gate mass for V400 operator: Gate swing angle Up to Up to Up to Up to Up to Up to1.5m 2m 2.5m 3m(#1) 3.5m(

Commenti su questo manuale